AmeriKooler Walk-In
Walk-Ins

AmeriKooler Walk-In

Model / SKU
QF080877WLFBRM-448A24-2705824-2705724-1481123-20619
01Warranty
  • One (1) Year Parts Warranty
  • One (1) Year Compressor Warranty (Two (2) Year Compressor for Pro3 Units/No Labor)
  • Fifteen (15) Year Panel Warranty
02Documents
03Maintenance schedule
PLEASE DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL MAINTENANCE
Daily
  • Clean both the inside and outside surface of the door with a clean damp cloth & mild soap solution.
  • Wipe all surfaces and make sure that it is dry.
  • Do not use any harsh cleaning liquids such as ammonia-based products. The interior and exterior of the door are either Acrylume, or Stainless Steel, any difficult stains should be cleaned with a non-abrasive metal polish.
  • The floor panels should be cleaned using a warm soapy solution or an approved NSF cleaning solution. Do not allow puddles to build up on the floor. Do not use any harsh chemicals to clean the floor.
Weekly
  • Inspect Thermocouple placement
  • Inspect the door to ensure proper closure and that nothing is interfering with the door from closing.
  • Check the thresholds on the door to ensure they are secure and secured to the concrete panel.
Monthly
  • Clean gaskets and door sweep. Use a warm water solution (one part baking soda) & dry all gaskets after cleaning.
  • Inspect the inside release mechanism to ensure proper operation.
  • Inspect light fixtures and observe for any moisture intrusion.
  • Inspect interior walls for missing cam lock plug holes. If missing, replace immediately to prevent moisture from entering.
  • Make sure that there are no obstructions around the unit.
Quarterly
  • Inspect the compressor for leaks, excessive moisture, and accumulation of dirt and debris.
  • Check for unusual noise or vibration.
  • Inspect wiring for signs of wear or discoloration and repair if needed.
  • Check and tighten all flare connections.
Bi-Annually
  • Inspect door gaskets and sweeps (replacements may be needed every three years)
  • Preventative maintenance appointment completed by qualified service technician recommended every 6-12 months
  • Clean evaporator/condenser coil and blades
  • Check the operation of all fans and ensure airflow is unobstructed.
  • Inspect electrical wiring and components
  • Check refrigeration cycle to ensure proper operation
Annually
  • Inspect door hinges
  • Inspect fastening hardware to make sure that they are tight and secure
  • Preventative maintenance appointment completed by qualified service technician recommended every 6-12 months